Filter Circuit Applications
Works with other components to form filter circuits for fundamental or harmonic currents in power-frequency AC systems.
AC Filter Circuits
ASMJ Series AC Filter Capacitor
Works with other components in power-frequency AC filter circuits and can also provide reactive power compensation.
Product Advantages
The ASMJ Series AC Filter Capacitor works with other components in power-frequency AC filter circuits and can also provide reactive power compensation.
It uses metallized polypropylene film with self-healing performance as the solid dielectric.
Capacitance tolerance is 0 to +3%. For three-phase capacitors, the maximum-to-minimum capacitance ratio measured between any two line terminals is ≤1.02.
Three capacitor families | Values are specified limits, not measured efficiency or energy savings.
0 to +3%; three-phase maximum-to-minimum capacitance ratio ≤1.02.
tan δ <0.0010 at rated power-frequency voltage.
Works with other components to form AC filter circuits; also supports reactive power compensation.
Works with other components to form filter circuits for fundamental or harmonic currents in power-frequency AC systems.
Can also be used for reactive power compensation to improve power factor.
Uses metallized polypropylene film with self-healing performance as the solid dielectric.
Features a capacitance tolerance of 0 to +3%. For three-phase capacitors, the maximum-to-minimum capacitance ratio measured between any two line terminals is ≤1.02.
Filter circuits for fundamental or harmonic currents in power-frequency AC systems
Used with reactors and other filter components in detuned or tuned filter assemblies
Reactive compensation where a filter-duty capacitor is specified
Plants with VFDs, rectifiers or similar loads that need filter-circuit capacitors
Filter or compensation cabinets on harmonic-rich low-voltage feeders
0.45–0.75 kV filter or compensation equipment in mechanical or electrical rooms
Pump and blower motor circuits that need filter-duty reactive compensation
Low-voltage filter or compensation cabinets serving UPS and mechanical plant
Pumping stations and public-building distribution that specify AC filter capacitors
Panel builders assembling power-frequency AC filter circuits with self-healing capacitors
| Capacitance Tolerance | Three-Phase Max. / Min. Capacitance Ratio | Loss Angle Tangent |
|---|---|---|
| 0 to +3% | ≤1.02 | tan δ <0.0010 |
Common Specifications
Loss angle tangent applies at rated power-frequency voltage. The three-phase ratio is measured between any two line terminals.
| Maximum Allowable Overvoltage | Maximum Allowable Overcurrent | Terminal-to-Terminal Withstand Voltage |
|---|---|---|
| 1.15Un · ≤8 h in every 24 h | 1.5In | 2.15Un / 2 s |
| Rated Voltage ≤600 V | Rated Voltage ≥600 V |
|---|---|
| 3.6 kV / 5 s | 7.2 kV / 5 s |
| Ambient Temperature | Relative Humidity | Altitude | Wall Clearance |
|---|---|---|---|
| -25°C to +50°C | <85% RH | <2000 m | >30 mm |
Common Specifications
Indoor installation. Avoid direct sunlight, rain, excessive dust and severe vibration. Ensure adequate ventilation and heat dissipation at high ambient temperatures.
Store indoors in a dry, non-corrosive atmosphere. Handle carefully and transport in the original factory packaging whenever possible.
| Model Specification | Rated Voltage (kV) | Rated Reactive Power (kvar) | Rated Frequency (Hz) | Rated Capacitance (µF) | Rated Current (A) | Enclosure Height (mm) | Outline Drawing |
|---|---|---|---|---|---|---|---|
| 0.45-5-3 | 0.45 | 5 | 50 | 78.6 | 6.4 | H130 | Figure 1 |
| 0.45-10-3 | 0.45 | 10 | 50 | 157.2 | 12.8 | H210 | Figure 1 |
| 0.45-15-3 | 0.45 | 15 | 50 | 235.8 | 19.2 | H210 | Figure 2 |
| 0.45-20-3 | 0.45 | 20 | 50 | 314.4 | 25.7 | H210 | Figure 2 |
| 0.45-25-3 | 0.45 | 25 | 50 | 393.0 | 32 | H210 | Figure 2 |
| 0.45-30-3 | 0.45 | 30 | 50 | 471.8 | 38.5 | H300 | Figure 2 |
| 0.45-40-3 | 0.45 | 40 | 50 | 628.8 | 51.3 | H210 | Figure 3 |
| 0.45-45-3 | 0.45 | 45 | 50 | 707.4 | 57.7 | H210 | Figure 3 |
| 0.525-5-3 | 0.525 | 5 | 50 | 57.8 | 5.5 | H130 | Figure 1 |
| 0.525-10-3 | 0.525 | 10 | 50 | 115.5 | 11.0 | H210 | Figure 1 |
| 0.525-15-3 | 0.525 | 15 | 50 | 173.2 | 16.5 | H210 | Figure 2 |
| 0.525-20-3 | 0.525 | 20 | 50 | 231.0 | 22.0 | H210 | Figure 2 |
| 0.525-25-3 | 0.525 | 25 | 50 | 288.8 | 27.5 | H160 | Figure 2 |
| 0.525-30-3 | 0.525 | 30 | 50 | 346.5 | 33.0 | H300 | Figure 2 |
| 0.525-40-3 | 0.525 | 40 | 50 | 462.0 | 44.0 | H210 | Figure 3 |
| 0.525-45-3 | 0.525 | 45 | 50 | 519.7 | 49.5 | H210 | Figure 3 |
| 0.75-5-3 | 0.75 | 5 | 50 | 28.3 | 3.9 | H130 | Figure 1 |
| 0.75-10-3 | 0.75 | 10 | 50 | 56.6 | 7.8 | H210 | Figure 1 |
| 0.75-15-3 | 0.75 | 15 | 50 | 84.9 | 11.7 | H210 | Figure 2 |
| 0.75-20-3 | 0.75 | 20 | 50 | 113.2 | 15.6 | H210 | Figure 2 |
| 0.75-25-3 | 0.75 | 25 | 50 | 141.5 | 19.5 | H210 | Figure 2 |
| 0.75-30-3 | 0.75 | 30 | 50 | 169.8 | 23.1 | H300 | Figure 2 |
| 0.75-40-3 | 0.75 | 40 | 50 | 226.4 | 30.8 | H210 | Figure 3 |
| 0.75-45-3 | 0.75 | 45 | 50 | 254.7 | 34.7 | H210 | Figure 3 |
Common Specifications
Model specifications belong to the BSMJ Series AC Filter Capacitor. Outline drawing numbers refer to the product introduction.
Single-phase products use the same installation dimensions as three-phase products of the same specification. Other specifications can be customized by agreement.
You can also attach drawings, product photos or test reports, if available.
It is selected as a capacitor element in an AC filter circuit. Together with other appropriately selected components, it forms a filter branch.
No. Harmonic-filtering behavior depends on the design of the complete branch, including its other components and the system conditions.
Yes. The product introduction states that it can also be used for reactive power compensation. Its voltage, capacitance and circuit arrangement still need to match the application.
The product introduction specifies a measured-to-rated capacitance difference of 0 to +3%. For a three-phase unit, the maximum-to-minimum capacitance ratio measured between line terminals must not exceed 1.02.
The product introduction specifies indoor installation, protection from rain and direct sunlight, and adequate ventilation and heat dissipation.
Please provide the rated voltage, required capacitance, number of phases and available details of the filter circuit and installation site.