Product Advantages

  • Up to 690 V AC Rated Operational Voltage
  • 20 Ie Inrush-Current Suppression
  • Up to 90 kvar at 400 V Capacitor Capacity
  • 50 / 60 Hz Frequency

Technological breakthrough

Compare Models at the Same Voltage

Capacitor switching capacities are grouped by their rated voltage.

Capacitor Switching Capacity

1. 380 V Ratings
CJ19-25
12.5 kvar
CJ19-32
20 kvar
CJ19-43
25 kvar
CJ19-63
37.3 kvar
2. 400 V Ratings
CJ19-95
50 kvar
CJ19-115
60 kvar
CJ19-150
80 kvar
CJ19-170
90 kvar

Selection Notes

  • 1
    Use the Stated Voltage

    Both groups use a 0-100 kvar scale. Ratingsapply at 380 V and 400 V respectively;compare models at the same voltage.

  • 2
    Check the Lower-voltage Rating

    Separate capacitor capacities at 220 V or 240V are listed in the technical parameter table.

  • 3
    Verify the Full Model

    Check insulation rating, coil voltage,contactor. dimensions and mounting before selecting the contactor.

Core Advantages

Capacitor Inrush Suppression

Dedicated current-limiting contacts and resistors suppress capacitor-bank making current. The specified inrush-current suppression capability is 20 Ie.

Reduced Switching Overvoltage

A current-limiting resistor reduces switching overvoltage when the capacitor bank is disconnected.

Direct Acting Double Break Structure

The direct-acting, double-break design uses contacts arranged in two layers, with a dedicated current-limiting arc chamber.

Capacitor Bank Selection by Rating

Model-specific capacitor capacities are provided at 220 or 240 V and 380 or 400 V, with ratings up to 90 kvar at 400 V.

Insulated Wiring Terminals

Insulation covers the wiring terminals to reduce exposure of the connection points.

Marked Coil Voltage

The rated coil voltage is marked on the coil terminals to help prevent incorrect connection.

Mounting Options by Model

Screw mounting and 35 mm or 75 mm DIN rails are available according to model. The 115 to 170 models support screws or two 35 mm rails.

Defined Coil Operating Limits

The specified closing range is 85% to 110% of coil voltage Us, and the opening range is 20% to 75% Us.

Product Applications

Low-voltage PFC capacitor banks

Switching capacitor banks in 50 Hz or 60 Hz power factor correction systems

Conventional capacitor-bank switching

Applications with high inrush current during energization where a capacitor-duty contactor is specified

Automatic compensation cabinets

Low-voltage cabinets that switch capacitor steps with a CJ19 series contactor

Industrial distribution compensation

Industrial feeders that use capacitor-duty contactors rather than general-purpose contactors

Commercial building PFC panels

Building electrical rooms with low-voltage power factor correction banks

50 Hz or 60 Hz AC systems

Installations within the stated frequency and operational-voltage limits

Screw or DIN-rail assemblies

Boards that use screw mounting, 35 mm or 75 mm rails, or two 35 mm rails on the 115 to 170 models

High-inrush capacitor switching

Banks that need the specified 20 Ie inrush-current suppression capability

OEM compensation boards

Panel builders selecting CJ19-25 to CJ19-170 by capacitor capacity and coil voltage

Replacement in capacitor duty

Replacing a general-purpose contactor where capacitor-bank making current requires a capacitor-duty device

Series Ratings

Rated Operational Voltage Frequency Inrush-current Suppression Capability
Up to 690 V AC 50 / 60 Hz 20 Ie

Capacitor Switching Ratings by Model

Model Rated Current (A) AC-6b Capacitor Capacity (kvar) 220 / 240 V Ratings Capacitor Capacity (kvar) 380 / 400 V Ratings
CJ19-25 17 at 380 V 6 at 220 V 12.5 at 380 V
CJ19-32 23 at 380 V 10 at 220 V 20 at 380 V
CJ19-43 29 at 380 V 15 at 220 V 25 at 380 V
CJ19-63 43 at 380 V 20 at 220 V 37.3 at 380 V
CJ19-95 72.2 at 400 V 35 at 240 V 50 at 400 V
CJ19-115 87 at 400 V 40 at 240 V 60 at 400 V
CJ19-150 115 at 400 V 46 at 240 V 80 at 400 V
CJ19-170 130 at 400 V 52 at 240 V 90 at 400 V

Insulation and Coil Ratings

Model Rated Insulation Voltage (V) Coil Power (VA) Making / Holding Weight (kg)
CJ19-25 500 70/9.5 0.44
CJ19-32 690 110/14 0.63
CJ19-43 690 110/14 0.64
CJ19-63 690 200/57 1.4
CJ19-95 690 300/57 1.5
CJ19-115 690 660/85.5 3.45
CJ19-150 690 660/85.5 3.45
CJ19-170 690 660/85.5 3.45

Common Specifications

Coil operating limits: closing at 85-110% Us; opening at 20-75% Us.

Specify the complete model, coil control voltage and frequency when ordering.

Overall and Mounting Dimensions

Model A max B max C max D max E F Mounting
CJ19-25 80 47 124 76 34/35 50/60 Screw or 35 mm rail
CJ19-32 90 58 132 86 40 48 Screw or 35 mm rail
CJ19-43 90 58 136 86 40 48 Screw or 35 mm rail
CJ19-63 132 79 150 - - - Screw or 35/75 mm rail
CJ19-95 135 87 158 - - - Screw or 35/75 mm rail
CJ19-115~170 200 120 192 155 - - Screw or two 35 mm rails

Common Specifications

Dimensions A-F in mm.

Operating and Installation Conditions

Ambient Temperature 24-hour Average Relative Humidity Altitude
-5°C to +40°C ≤+35°C ≤50% at +40°C · Up to 90% at +20°C ≤2000 m

Installation Requirements

Pollution Degree Installation Category Mounting Inclination
3 III Within ±5° from vertical

Common Specifications

Take measures against condensation caused by temperature changes.

Install where there is no significant shaking, impact or vibration.

Please Share the Details You Know:

  • Product or model
  • Application or problem to solve
  • Required specifications, such as voltage, frequency or capacity
  • Quantity and delivery requirements

You can also attach drawings, product photos or test reports, if available.

Share Your Requirements

FAQ

What is a CJ19 contactor used for?

It is designed to switch low-voltage capacitor banks in reactive power compensation equipment. Its current-limiting structure reduces capacitor-bank making current and helps limit switching overvoltage.

Can I use a general-purpose contactor instead?

For a capacitor branch, select a device rated for capacitor switching. The CJ19 information specifies an AC-6b capacitor-switching duty and gives capacitor capacity by model; selection should follow the actual operating voltage and bank kvar.

What operating voltage and frequency are covered?

The specified product information states a rated operational voltage of up to 690 V at 50 Hz or 60 Hz. Confirm the selected model, coil voltage and capacitor-bank rating for the project.

How do I choose the contactor size?

Match the capacitor-bank kvar and operating voltage to the applicable model rating, then confirm the control-coil voltage, auxiliary-contact arrangement and mounting method. Do not select from the model number or rated current alone.

Does the contactor eliminate capacitor inrush current?

No. Its current-limiting contacts and resistor are designed to reduce making current and switching overvoltage. The complete branch still needs correctly selected capacitors, protection and wiring.

What details should I include in an inquiry?

Provide the system voltage and frequency, capacitor kvar per switched step, required coil control voltage, auxiliary-contact requirement, mounting method and order quantity.