Live Measurement and Status Display
View grid voltage, current, power factor, active and reactive power, harmonic distortion, frequency, capacitor capacity and fault alarms on the LCD.
ZKF32
Power Factor Controller with Modbus & USB
An LCD controller for low-voltage capacitor banks, with network links for smart capacitors and composite switches.
Product Advantages
View grid voltage, current, power factor, active and reactive power, harmonic distortion, frequency, capacitor capacity and fault alarms on the LCD.
Reactive power measurement guides capacitor switching to reduce switching oscillation and compensation dead zones.
Configure capacitor-bank capacities separately to match the installed compensation steps.
Supports common, individual-phase and mixed compensation arrangements with the corresponding sampling and control wiring.
Run automatic compensation during service and use manual switching to check the connected capacitor banks.
Overvoltage, undervoltage, harmonic, low-current and low power factor protection work alongside self-check and watchdog functions.
RJ45 connects compatible smart capacitors or composite switches. RS485 with MODBUS supports data upload, operating statistics and remote capacitor switching.
Export event records through USB for review during operation and maintenance.
LCD control in LV cabinets
RJ45 link to compatible units
RJ45 link to compatible switches
Common-compensation control wiring
Individual-phase sampling wiring
Common and individual-phase steps
Automatic switching in service
Manual switching to check banks
MODBUS upload and remote switching
USB export for maintenance review
| System Voltage | Frequency | Sampling Current | Power Consumption |
|---|---|---|---|
| AC 400 V ±20% | 50 Hz / 60 Hz ±5% | 0-5 A | 6 W |
| Voltage | Current | Frequency | Power Factor | Active Power | Reactive Power |
|---|---|---|---|---|---|
| ±0.5% | ±0.5% | ±0.1% | ±1.0% | ±1.0% | ±1.0% |
| Interface / Output | Specification | Configuration |
|---|---|---|
| RS485 | MODBUS; communication current: 10 mA | Standard output |
| RJ45 Network | Compatible smart capacitors / composite switches | Output code 32 |
| DC Output | Maximum DC 12 V, 50 mA | Model / order dependent; output code 16 |
| Relay Dry Contacts | Maximum AC 220 V, 2 A | Model / order dependent; output code 16 |
Common Specifications
RJ45 Auto ID: 9600 baud for smart capacitors; 19200 baud for composite switches.
For compatible combined smart-capacitor / composite-switch systems: SK_GY protocol, 9600 baud.
| Switch-in / Switch-out Delay | Capacitor Discharge Time | Event Records |
|---|---|---|
| 0-99.9 s | 0-999 s | USB export |
Common Specifications
Common, individual-phase and mixed compensation. Automatic and manual operation; capacitor-bank capacity can be configured separately.
Protection: overvoltage, undervoltage, voltage / current harmonics, low current and low power factor. Self-check and watchdog functions.
| Ambient Temperature | Relative Humidity | Altitude | Atmospheric Pressure |
|---|---|---|---|
| -20°C to +65°C | 20-90% at 40°C | ≤2500 m | 79.5-106 kPa |
Common Specifications
No explosive hazard, corrosive or insulation-damaging gases, conductive dust, severe vibration, or rain / snow ingress.
Standards: JB/T 9663-2013; DL/T 597-1996.
| Overall Dimensions | Panel Cutout |
|---|---|
| 120 × 120 × 85 mm | 113 × 113 mm |
You can also attach drawings, product photos or test reports, if available.
Its RJ45 network interface is described for compatible intelligent capacitors or composite switches. Provide the connected device model so compatibility can be checked.
RJ45 is used for the compatible capacitor or switch network. RS485 is used for communication with an upper-level monitoring device.
It displays electrical measurements, voltage and current harmonic distortion, capacitor capacity, switching status and fault alarms.
Yes. The manual lists all-Δ and Δ + Y mixed capacitor configurations. The controller setting must match the connected circuits.
Yes. The manual lists USB export of event records.
No. The manual states that relay dry-contact and other output arrangements depend on the model or order. Confirm the required interface before ordering.