Industry Overview

Data centers require highly reliable and stable power to support servers, UPS systems, cooling equipment, network infrastructure and other critical loads.

With increasing rack density, AI computing and high-performance computing applications, modern data centers are facing higher power density, faster load changes and more complex power quality requirements.

 

Power Quality Problems

  • Harmonic DistortionUPS systems, server power supplies, VFD-driven cooling equipment and other nonlinear loads can generate significant harmonic currents, particularly the 3rd, 5th, 7th, 11th and 13th harmonics.
  • High Neutral CurrentTriplen harmonics, especially the 3rd harmonic, can accumulate in the neutral conductor of three-phase four-wire systems, increasing neutral current and thermal stress.
  • Reactive Power & Power FactorChanging operating conditions can cause reactive power fluctuations and unstable power factor, increasing unnecessary current in the distribution system.
  • Three-Phase Load ImbalanceUneven single-phase IT and auxiliary loads may create current imbalance between phases and reduce distribution efficiency.
  • Electrical OverheatingHarmonics and excessive current can increase losses and temperature in transformers, cables, neutral conductors and other distribution equipment.

Power Quality Challenges

  • High Reliability RequirementsPower disturbances can affect sensitive IT, communication and monitoring equipment, making electrical stability critical to continuous data center operation.
  • High Concentration of Nonlinear LoadsUPS systems, switched-mode power supplies, cooling equipment and other power electronic loads operate simultaneously, creating a complex harmonic environment.
  • Rapid Load VariationComputing and cooling loads can change quickly, requiring compensation systems to respond dynamically to changing electrical conditions.
  • Complex Distribution ArchitectureRedundant power paths, UPS systems, PDUs and multiple distribution levels make it more difficult to determine the correct monitoring and compensation points.

 

Power Quality Solution

  • AHF — Harmonic MitigationActive Harmonic Filters dynamically compensate harmonic currents generated by UPS systems, server power supplies, VFDs and other nonlinear loads, helping reduce harmonic impact on transformers, cables and distribution equipment.
  • SVG — Dynamic Reactive Power CompensationStatic Var Generators provide fast reactive power compensation under changing load conditions, helping maintain a stable power factor and reduce unnecessary reactive current.
  • ASVG — Integrated Power Quality CompensationFor applications where reactive power, harmonics and three-phase imbalance occur simultaneously, ASVG provides integrated dynamic compensation within the available system capacity.
  • Power Quality MonitoringContinuous monitoring of harmonic distortion, power factor, reactive power, phase imbalance and load conditions helps identify abnormalities and optimize compensation performance.

 

Recommended System Architecture

Power Quality Monitoring
Installed at the main low-voltage bus or PCC to monitor THD, power factor, reactive power and phase imbalance.

AHF
Installed at the main distribution bus or close to major nonlinear loads such as UPS systems and VFD-driven cooling equipment to reduce harmonic current before it propagates upstream.

SVG
Installed at the main low-voltage bus where rapid reactive power variation or unstable power factor requires dynamic compensation.

ASVG
Used where reactive power, harmonics and three-phase imbalance need to be addressed together within one compensation system.

 

Case Studies

Proven in Real Projects

Selected field projects where this solution has been applied. Click any card to see the full case with measured results.

CONTACT US

Please share the details you know:

• Product or model
• Application or problem to solve
• Required specifications, such as voltage, frequency or capacity
• Quantity and delivery requirements

You can also attach drawings, product photos or test reports, if available.

Share Your Requirements