Three-phase AC sampling
Samples voltage and current on all three phases.
JKWF-12
Three Phase Power Factor Controller
A three-phase reactive-power controller with configurable capacitor steps and static or dynamic outputs.
Product Advantages
Samples voltage and current on all three phases.
Displays power factor, voltage, current, reactive power and capacitor switching status, with a data refresh interval of no more than one second.
Select power-factor cyclic switching or reactive-power-based compensation. Reactive power control can skip an oversized step to avoid overcompensation.
Automatic operation follows the configured compensation settings. Manual operation allows individual switching checks during commissioning.
Set capacitor capacity and phase assignment by circuit to suit common or individual-phase compensation arrangements.
Configure between one and twelve capacitor control circuits to match the number of installed steps.
Choose relay contacts for contactor switching or 12 V DC outputs for compatible composite or thyristor switching devices.
Overvoltage, undervoltage and zero-current alarms inhibit switching when the corresponding abnormal condition is detected.
Three-phase V and I sampling
Common-compensation step control
Individual-phase step assignment
Relay contacts 5 A / 250 V
DC 12 V, 30 mA outputs
Follows configured control settings
Step checks during commissioning
One to twelve control circuits
OV, UV and zero-current inhibit
Cutout 113 × 113 mm, depth 95 mm
| Power Supply | Measured Voltage | Frequency | CT Secondary Input |
|---|---|---|---|
| 380 V ±20% | 100-500 V | 47-53 Hz | 0-5 A |
| Voltage / Current Accuracy | Active / Reactive Power Accuracy | Power Factor Accuracy | Data Refresh |
|---|---|---|---|
| ±0.5% | ±1.0% | ±1.0% | ≤1 s |
Common Specifications
Primary current measurement: 0-6000 A. Secondary-current sensitivity: 50 mA.
Measured power factor: 0.200 lagging to 0.200 leading. Active power: 0-6553 kW; reactive power: 0-6553 kvar.
| Configuration | Output | Control Circuits | Compensation Control |
|---|---|---|---|
| Static | Relay dry contacts: 5 A / 250 V, resistive load | 1-12 | Power factor / reactive power control |
| Dynamic | DC 12 V, 30 mA per circuit | 1-12 | Power factor / reactive power control |
Common Specifications
Static or dynamic output configuration shall be specified when ordering.
Common or individual-phase capacitor-step assignment. Overvoltage, undervoltage and zero-current alarm protection.
| Ambient Temperature | Storage Temperature | Altitude |
|---|---|---|
| -20°C to +60°C | -40°C to +70°C | ≤2500 m |
Common Specifications
Installation environment: no corrosive gas, conductive dust, flammable or explosive medium, severe vibration, or rain / snow ingress.
| Panel Cutout | Embedded Depth |
|---|---|
| 113 × 113 mm | 95 mm |
You can also attach drawings, product photos or test reports, if available.
It supports up to 12 control circuits.
Yes. Each circuit can be assigned to three-phase compensation or to phase A, B or C, with its capacity set separately.
The manual describes relay contact output for static control and 12 V output for dynamic control. Specify the switching device and control method when ordering.
Yes. Both modes are available through the controller settings.
In reactive-power control mode, it checks whether a proposed step would cause overcompensation. If possible, it selects a smaller available step instead.
Check for over-voltage, under-voltage or low-current alarms, and verify that voltage and current sampling follow the correct phase sequence.