Integrated Measurement and Control
An intelligent measurement and control unit is incorporated into the complete compensation device.
NH Series
Intelligent Power Capacitor
The NH Series integrates the essential measurement, switching, protection and capacitor components into a complete intelligent compensation unit.
Product Advantages
An intelligent measurement and control unit, a dedicated zero-crossing switching unit and an intelligent protection unit are built into the device.
The device uses either two low-voltage self-healing capacitors in delta connection or one low-voltage self-healing capacitor in star connection.
An intelligent measurement and control unit is incorporated into the complete compensation device.
A dedicated zero-crossing switching unit is integrated into the device.
An intelligent protection unit is built into the compensation device.
The device uses either two low-voltage self-healing capacitors in delta connection or one low-voltage self-healing capacitor in star connection.
Low-voltage cabinets that need measurement, switching, protection and capacitors in one unit
HVAC, lighting and elevator loads served by compact intelligent compensation
Motor and process feeders that benefit from zero-crossing switching
Occupancy-varying loads where an integrated intelligent unit simplifies installation
Auxiliary low-voltage systems that need compact reactive compensation with built-in protection
Pump and blower compensation using a complete intelligent unit
Mechanical and electrical rooms with limited space for discrete capacitor assemblies
Pumping stations and public buildings using co-compensation or split-compensation units
Panel builders assembling NH Series intelligent units into low-voltage boards
Replacing discrete contactors, controllers and capacitors with one integrated unit
| Ordering Model | Compensation Method | Capacitor Rated Voltage (V) | Rated Reactive Power (kvar) | Dimensions L × W × H (mm) | Mounting Dimensions (mm) |
|---|---|---|---|---|---|
| NHZNGB/450-5+5 | Co-compensation | 450 | 10 | 385×78×235 | 50×363 |
| NHZNGB/450-10+5 | Co-compensation | 450 | 15 | 385×78×235 | 50×363 |
| NHZNGB/450-10+10 | Co-compensation | 450 | 20 | 385×78×235 | 50×363 |
| NHZNGB/450-15+15 | Co-compensation | 450 | 30 | 385×78×265 | 50×363 |
| NHZNGB/450-20+10 | Co-compensation | 450 | 30 | 385×78×305 | 50×363 |
| NHZNGB/450-20+20 | Co-compensation | 450 | 40 | 385×78×305 | 50×363 |
| NHZNGB/450-25+25 | Co-compensation | 450 | 50 | 385×78×325 | 50×363 |
| NHZNGB/450-30+30 | Co-compensation | 450 | 60 | 385×78×325 | 50×363 |
| NHZNFB/250-5 | Split compensation | 250 | 5 | 385×78×235 | 50×363 |
| NHZNFB/250-10 | Split compensation | 250 | 10 | 385×78×235 | 50×363 |
| NHZNFB/250-15 | Split compensation | 250 | 15 | 385×78×265 | 50×363 |
| NHZNFB/250-20 | Split compensation | 250 | 20 | 385×78×265 | 50×363 |
| NHZNFB/250-25 | Split compensation | 250 | 25 | 385×78×305 | 50×363 |
| NHZNFB/250-30 | Split compensation | 250 | 30 | 385×78×305 | 50×363 |
Common Specifications
Integrated units include intelligent measurement and control, zero-crossing switching and intelligent protection.
Capacitor configuration: two delta-connected low-voltage self-healing capacitors or one star-connected low-voltage self-healing capacitor.
You can also attach drawings, product photos or test reports, if available.
It integrates measurement and control, zero-crossing switching, protection and power capacitors into a compensation unit. A conventional capacitor is one component of a compensation system.
Yes. The product introduction lists separate models for common compensation and individual-phase compensation. They can be selected according to the system arrangement.
The switching unit is integrated into the product. The need for an external controller depends on how the compensation units are configured and networked.
Yes. The manual describes modular networking of multiple intelligent capacitor units. The allowable circuit count depends on whether they operate under a capacitor unit acting as master or a matching external controller.
The manual lists protection relating to over-voltage, under-voltage, over-temperature, over-current, short circuit and phase loss.
The product introduction describes it as an integrated reactive power compensation unit; it does not specify harmonic-filtering performance. If the site has significant harmonics, share the measurements so the complete compensation arrangement can be assessed.