Get A Quote

Home > Products > Power Capacitors > BSMJY Series Cylindrical Power Capacitor

return

Cylindrical Power Capacitor

Cylindrical Power Capacitor

BSMJY Series Cylindrical Power Capacitor

Provides reactive power compensation for power-frequency AC systems with a nominal voltage of 1000 V and below.

Product Advantages

  • 1000 V and below System Voltage
  • ≤75 V in 3 min Built-in Discharge
  • 1.1Un / 1.3In Voltage / Current Limits
  • Overpressure protection Automatic Disconnect

Product Description

The BSMJY Series provides reactive power compensation for power-frequency AC systems with a nominal voltage of 1000 V and below.

It improves power factor, reduces reactive-power losses in transmission lines and supports improved voltage quality.

Built-in discharge resistors reduce residual voltage from √2Un to 75 V or below within 3 minutes after disconnection, and overpressure protection automatically disconnects the capacitor from the power supply if internal pressure rises abnormally.

Cylindrical power flow and capacitor compensation

Technological breakthrough

Declared Specification Limits

Three capacitor families | Values are specified limits, not measured efficiency or energy savings.

Voltage and Current Limits

1. Maximum Allowable Overvoltage

For all three families: no more than 8 h in every 24 h.

BSMJY Cylindrical
1.1Un
BSMJ LV Power
1.1Un
BSMJ AC Filter
1.15Un
2. Maximum Allowable Overcurrent

Values are expressed as multiples of rated current In.

BSMJY Cylindrical
1.3In
BSMJ LV Power
1.3In
BSMJ AC Filter
1.5In

Product Specification Details

  • 1
    Capacitance Tolerance

    -5% to +10%; three-phase maximum-to-mil m capacitance ratio <1.08.

  • 2
    Loss Angle Tangent

    tan δ <0.0012 at rated power-frequency voltage.

  • 3
    Self-Discharge

    Residual voltage falls to ≤75 V within 3 min after disconnection from √2Un.

Core Advantages

Power Factor Improvement

Improves power factor, reduces reactive-power losses in transmission lines and supports improved voltage quality.

Application-Oriented Design

The structural design is suitable for high ambient temperatures and applications with significant system-voltage fluctuations, within the specified operating limits.

Built-in Discharge Resistors

Built-in discharge resistors reduce residual voltage from √2Un to 75 V or below within 3 minutes after disconnection.

Overpressure Protection

Overpressure protection automatically disconnects the capacitor from the power supply if internal pressure rises abnormally, helping prevent fault escalation.

Product Applications

Low-voltage distribution

Reactive power compensation on power-frequency AC systems of 1000 V and below

High ambient temperature rooms

Cylindrical units specified for elevated ambient temperature within the rated −25°C to +50°C range

Sites with voltage fluctuation

Applications with significant system-voltage fluctuations, within the specified 1.1Un operating limit

Motor control centers

Power factor improvement for motor feeders in industrial plants

Compact capacitor banks

Cylindrical stud-mounted capacitors where enclosure diameter and height are constrained

Commercial buildings

HVAC and lighting loads needing low-voltage reactive compensation

Water and wastewater

Pump and blower motor compensation in municipal and industrial plants

Manufacturing lines

Continuous motor-driven equipment with lagging power factor

OEM capacitor modules

Panel builders assembling cylindrical low-voltage compensation modules

Utility and campus feeders

0.4–0.525 kV three-phase or 3YN compensation cabinets

Capacitance and Loss

Capacitance Tolerance Three-Phase Max. / Min. Capacitance Ratio Loss Angle Tangent
-5% to +10% ≤1.08 tan δ <0.0012

Common Specifications

Loss angle tangent applies at rated power-frequency voltage. The three-phase ratio is measured between any two line terminals.

Voltage and Current Limits

Maximum Allowable Overvoltage Maximum Allowable Overcurrent Terminal-to-Terminal Withstand Voltage Self-Discharge
1.1Un · ≤8 h in every 24 h 1.3In 2.15Un / 2 s ≤75 V within 3 min from √2Un

Terminal-to-Enclosure Withstand Voltage

Rated Voltage ≤600 V Rated Voltage ≥600 V
3.6 kV / 5 s 7.2 kV / 5 s

Operating Conditions

Ambient Temperature Relative Humidity Altitude
-25°C to +50°C ≤50% RH at 40°C · ≤90% RH at 20°C <2000 m

Common Specifications

Standard: GB/T12747.1. Intended for power-frequency AC systems with a nominal voltage of 1000 V and below.

Store indoors in a dry, non-corrosive atmosphere. Avoid direct sunlight, rain, excessive dust and severe vibration. Keep at least 30 mm clearance and ensure adequate ventilation and heat dissipation.

Model Selection

Model Specification Rated Voltage (kV) Rated Reactive Power (kvar) Rated Capacitance (µF) Rated Current (A) Housing Diameter M (mm) Enclosure Height (mm) Mounting Stud
0.4-5-3 0.4 5 99.5 7.2 76 240 M12
0.4-10-3 0.4 10 199 14.4 76 240 M12
0.4-12-3 0.4 12 238.9 17.3 76 240 M12
0.4-15-3 0.4 15 298.6 21.7 86 240 M12
0.4-16-3 0.4 16 318.5 23.1 86 240 M12
0.4-20-3 0.4 20 398.1 28.9 96 240 M16
0.4-25-3 0.4 25 497.6 36.1 106 240 M16
0.4-30-3 0.4 30 597.1 43.3 116 290 M16
0.45-5-3 0.45 5 78.6 6.4 76 290 M12
0.45-10-3 0.45 10 157.3 12.8 76 240 M12
0.45-12-3 0.45 12 188.7 15.4 76 240 M12
0.45-14-3 0.45 14 220.2 18 76 240 M12
0.45-15-3 0.45 15 235.9 19.2 86 240 M12
0.45-16-3 0.45 16 251.6 20.5 86 240 M12
0.45-20-3 0.45 20 314.5 25.7 96 240 M16
0.45-25-3 0.45 25 393.2 32.1 106 240 M16
0.45-30-3 0.45 30 471.8 38.5 106 290 M16
0.45-40-3 0.45 40 629.1 51.3 136 290 M16
0.48-5-3 0.48 5 69.1 6 76 240 M12
0.48-10-3 0.48 10 138.2 12 76 240 M12
0.48-15-3 0.48 15 207.3 18 76 240 M12
0.48-20-3 0.48 20 276.5 24.1 86 240 M16
0.48-25-3 0.48 25 345.6 30.1 96 240 M16
0.48-30-3 0.48 30 414.7 36.1 116 240 M16
0.48-40-3 0.48 40 552.9 48.1 136 290 M16
0.525-5-3 0.525 5 57.8 5.5 76 240 M12
0.525-10-3 0.525 10 115.5 11 76 240 M12
0.525-15-3 0.525 15 173.3 16.5 86 240 M16
0.525-20-3 0.525 20 231.1 22 96 240 M16
0.525-25-3 0.525 25 288.9 27.5 106 290 M16
0.525-30-3 0.525 30 346.4 33 116 290 M16
0.525-40-3 0.525 40 462.2 44 136 290 M12
0.25-5-3YN 0.25 5 84.9 6.7 76 240 M12
0.25-10-3YN 0.25 10 169.8 13.3 86 240 M16
0.25-15-3YN 0.25 15 254.7 20 96 240 M16
0.25-20-3YN 0.25 20 339.7 26.7 106 290 M16
0.25-25-3YN 0.25 25 424.6 33.3 116 290 M16
0.25-30-3YN 0.25 30 509.5 40 136 290 M12
0.28-5-3YN 0.28 5 67.7 6 76 240 M12
0.28-10-3YN 0.28 10 135.4 11.9 86 240 M16
0.28-15-3YN 0.28 15 203.1 17.9 96 240 M16
0.28-20-3YN 0.28 20 270.8 23.8 106 240 M16
0.28-25-3YN 0.28 25 338.5 29.8 106 290 M16
0.28-30-3YN 0.28 30 406.2 35.7 136 240 M16
0.3-5-3YN 0.3 5 58.9 5.6 76 240 M12
0.3-10-3YN 0.3 10 118 11.1 86 240 M12
0.3-15-3YN 0.3 15 176.9 16.7 96 240 M16
0.3-20-3YN 0.3 20 235.9 22.2 106 290 M16
0.3-25-3YN 0.3 25 294.8 27.8 106 290 M16
0.3-30-3YN 0.3 30 353.8 33.3 136 290 M16

Common Specifications

Model specifications belong to the BSMJY Series. Diameter M, enclosure height and mounting stud sizes are listed separately.

Please Share the Details You Know:

  • Product or model
  • Application or problem to solve
  • Required specifications, such as voltage, frequency or capacity
  • Quantity and delivery requirements

You can also attach drawings, product photos or test reports, if available.

Share Your Requirements

FAQ

Where is the BSMJY series used?

It is a cylindrical capacitor element for power-factor correction in low-voltage AC systems. The cylindrical housing and mounting dimensions should be checked against the cabinet layout.

Does it have built-in discharge and pressure protection?

Yes. The product introduction lists built-in discharge resistors and overpressure protection. The latter is designed to disconnect the capacitor if internal pressure rises abnormally.

How quickly does its residual voltage decrease after disconnection?

The product introduction specifies a decrease from √2Un to 75 V or below within 3 minutes. Always verify a safe voltage before touching the terminals.

Can it be used without checking site harmonics?

Harmonic sources should be identified before installation. The BSMJY is a power capacitor, and the product introduction does not describe it as a standalone harmonic filter.

What space should be allowed for installation?

Check the selected model’s diameter, height and mounting stud. The installation notes also require at least 30 mm clearance and adequate ventilation.

What details are needed to select a replacement?

Provide the existing unit’s nameplate model, rated voltage, kvar rating, connection arrangement and available mounting space. This helps check both electrical and mechanical fit.